Berlia Pipes: Your Trusted Partner for TEC/TSEC Approved PLB HDPE Duct Solutions

When it comes to protecting India’s telecommunications infrastructure, the quality of duct pipes is paramount. Berlia Pipes, with its rich legacy dating back to 1975, stands at the forefront of manufacturing TEC/TSEC approved PLB HDPE duct pipes that meet the highest industry standards. With decades of experience and state-of-the-art manufacturing facilities, the company has become a trusted name for telecom projects across India
The Legacy of Excellence
Berlia Electricals Pvt. Ltd. has been a pioneer in the polymer industry, with the Berlia Group accumulating over 42 years of manufacturing experience in plastic and polymer products. The company was one of the very first manufacturers in India to acquire the technology and equipment for establishing a complete manufacturing facility for PLB-HDPE Ducts. This first-mover advantage has positioned Berlia as a leader in telecom duct solutions.
Manufacturing Excellence and Capacity
Berlia Pipes operates with impressive manufacturing capabilities:
-
Eight advanced production lines at their Rai Industrial Estate facility in Sonipat, Haryana
-
Annual production capacity exceeding 4,000 metric tonnes of HDPE pipes
-
Monthly manufacturing capacity of 2,000 Metric Tonnes of HDPE Pipes
-
World-class infrastructure with a fully equipped laboratory for testing and R&D
The company sources its raw materials from reputable domestic suppliers, including Indian Oil, GAIL, and HMEL, and operates an in-house ISI-approved testing laboratory where every batch undergoes stringent quality checks. This meticulous approach ensures that Berlia products consistently meet government specifications and quality standards.
Understanding PLB HDPE Duct Technology
PLB (Permanently Lubricated) HDPE ducts are co-extruded with an inner layer of solid silicone that provides permanent lubrication. This innovative design ensures an exceptionally low coefficient of friction, facilitating smooth cable installation through both blowing and pulling techniques. The silicone coating does not react with water, allowing for water flushing to clear blockages when necessary.
TEC/TSEC Certification: Ensuring Quality Compliance
TEC (Telecommunications Engineering Center) and its certification wing TSEC provide the benchmark for telecom infrastructure quality in India. Berlia’s PLB ducts comply with crucial specifications including TEC/DOT/GR/TX/CDS-008/03/MAR-11 and DOT Specification GR/CDS-08/02 Nov. 2004 amendments
Key performance characteristics of TEC-approved Berlia ducts include:
-
Environment Stress Crack Resistance (ESCR): Ensures long-term durability under environmental stresses
-
Impact Resistance: Protects against installation and external damage
-
Crush Resistance: Maintains integrity under soil and traffic loads
-
Low Coefficient of Friction: Enables smooth cable installation
-
High UV Protection: Prevents degradation during storage and installation
-
High Temperature Resistance: Suitable for diverse climatic conditions
Standard Sizes for Every Application
Berlia manufactures PLB ducts in various sizes to suit different telecom deployment requirements:
32/26 mm (OD/ID) – Ideal for FTTH (Fiber to the Home) deployments, this size is perfect for last-mile connectivity and residential network rollouts.
40/33 mm – The most widely used standard diameter for general telecom applications, offering a balanced solution for various network requirements.
50/42 mm – Designed for heavy-duty main trunk routes and multi-cable pulls, this larger diameter accommodates higher cable counts and is preferred for backbone network infrastructure
Color Coding and Application Sectors
Comprehensive Support for National Infrastructure
Berlia Pipes has earned the trust of prestigious public sector clients, including DRDO, BHEL, PGCIL, Indian Railways, and the Airport Authority of India. The company’s product portfolio extends beyond PLB ducts to include:
Installation Flexibility and Jointing Solutions
Berlia Pipes maintains BIS, ISO, and ASTM certifications, ensuring products meet global standards. The company’s commitment to innovation is evident in its specialized offerings like fire-resistant and anti-rodent ducts, which address specific industry challenges in sectors such as oil and gas, telecommunications, and power distribution.
With a vision to become one of India’s top HDPE pipe manufacturers, Berlia is strategically planning to scale its production capabilities to manufacture pipes up to 2,500 mm (2.5 meters) in diameter. This ambitious goal reflects the company’s dedication to supporting India’s expanding infrastructure needs
Partner with Berlia for Your Telecom Projects
Whether you’re involved in BharatNet Phase II/III rollouts, BSNL network expansions, RailTel projects, or NHAI highway duct installations, Berlia Pipes offers the reliability, quality, and technical expertise you need. With decades of experience, TEC/TSEC compliance, and a commitment to innovation, Berlia remains your trusted partner for PLB HDPE duct solutions.
The Gold Standard of Underground Optical Fibre Protection: How Berlia PLB HDPE Ducts Comply with TEC/GR/FA/CDS-008/04/AUG-19
When you’re laying optical fibre cable underground, the duct you choose is the difference between a network that performs flawlessly for 50 years and one that fails under pressure, moisture, or friction. In India, the benchmark for this critical infrastructure component is set by the Telecommunication Engineering Centre (TEC) under the Department of Telecommunications, Government of India.
The specification TEC/GR/FA/CDS-008/04/AUG-19 — Generic Requirements for Permanently Lubricated HDPE Telecom Ducts for Use as Underground Optical Fibre Cable Conduits — is the definitive document that governs the design, material, testing, and performance of PLB HDPE ducts. At Berlia, we manufacture ducts that don’t just meet these requirements — we embody every clause, table, and annexure of this standard.
This blog walks you through the TEC GR’s technical requirements and demonstrates how Berlia’s PLB HDPE ducts comply with each one, giving you complete confidence in your underground optical fibre deployment.
1. Product Description: Two-Layer Co-Extruded Construction
The TEC GR mandates that a PLB HDPE duct consists of two concentric layers:
-
Outer Layer: High Density Polyethylene (HDPE)
-
Inner Layer: A solid, permanently lubricated polymeric material co-extruded with the outer layer
The inner lubricant layer must be:
-
A solid layer of uniform thickness
-
White in colour and clearly visible in cross-section
-
Continuous throughout the duct’s life
-
Formulated to provide a permanent low-friction boundary layer between the duct’s inner surface and the optical fibre cable
Berlia Compliance: Our PLB HDPE ducts are manufactured using advanced co-extrusion technology that bonds the inner lubricant layer integrally with the HDPE outer layer. The white inner layer is uniformly thick, visually distinct, and permanently embedded — it will not peel, flake, or migrate during storage, installation, or decades of service.
2. Raw Material Requirements
2.1 Outer Layer HDPE Resin
The TEC GR specifies that the base HDPE resin must conform to IS: 7328 and meet the following Table-1 requirements:
| Property | TEC Requirement | Berlia Compliance |
|---|---|---|
| Density | 0.940–0.958 g/cc at 27°C | ✅ Compliant |
| Melt Flow Rate (MFR) | 0.2–1.1 g/10 min at 190°C & 5 kg | ✅ Compliant |
| Tensile Strength at Yield | ≥ 20 N/mm² (ASTM D 638, Type-IV) | ✅ Compliant |
| Elongation at Break | > 600% (ASTM D 638, Type-IV) | ✅ Compliant |
| Flexural Modulus at 1% strain | ≥ 690 N/mm² (ASTM D 790) | ✅ Compliant |
| Hardness, Shore-D | 60–65 units (ASTM D 2240) | ✅ Compliant |
| Heat Deflection Temperature | ≥ 65°C at 45 g/mm² (ASTM D 648) | ✅ Compliant |
| Environmental Stress Crack Resistance | 96 hrs with 10% Igepal CO-630 at 50°C, no cracks (ASTM D 1693) | ✅ Compliant |
| Weathering (UV) | After 720 hrs exposure, tensile strength variation ≤ 20% | ✅ Compliant |
| OIT (Aluminium Pan) | ≥ 30 minutes (Annexure-I) | ✅ Compliant |
| UV Stabiliser Content | Hindered Amine Light Stabiliser ≥ 0.15% | ✅ Compliant |
2.2 Inner Lubricant Layer
-
Density: 0.940–0.958 g/cc at 27°C
-
Non-toxic, safe handling
-
White in colour, clearly visible in cross-section
-
Continuous, integral with HDPE, will not come out during storage or usage
Berlia Compliance: Our inner lubricant layer is a specially formulated polymeric compound that meets the density specification and is co-extruded to form a permanent, inseparable bond with the HDPE outer layer. It remains stable throughout the duct’s 50+ year design life.
2.3 Raw Material Handling & Additives
-
Antioxidants must be physiologically harmless
-
No additives that impair long-term physical/chemical properties
-
Single-pass rework material ≤ 10%
-
Moisture content < 0.1% before extrusion
-
UV stabilisers for minimum 8 months open storage protection
-
Service life > 50 years including permanent lubricant
-
Ash content of colour master batch ≤ 12%
Berlia Compliance: We source only TEC/CACT-approved HDPE resins, maintain strict moisture control with inline dryers, use food-grade antioxidants, and limit rework to well below 10%. Our colour master batches meet the ash content requirement, and our formulations are engineered for a 50-year service life.
3. Completed Duct Requirements
3.1 Visual Inspection
Ducts must be free from blisters, shrink holes, flaking, chips, scratches, roughness, breaks, and other defects. They must be smooth, clean, round, and cut square with the axis.
Berlia Compliance: Every Berlia duct undergoes 100% inline visual inspection and post-production quality checks. Our extrusion lines are equipped with laser diameter gauges and surface defect detection systems.
3.2 Colour Options
-
Available in 8 colours: Green, Orange, Blue, Yellow, Brown, Violet, Grey, Red
-
Uniform colour throughout
-
Four equispaced continuous white longitudinal stripes (min. 3 mm width)
-
Stripes co-extruded with the duct
-
Stripe material same as base HDPE compound
Berlia Compliance: We offer all eight standard colours with co-extruded white stripes that are uniform, continuous, and meet the 3 mm minimum width requirement. Custom colour matching is also available.
3.3 Dimensions
| Nominal Size | Outside Diameter Tolerance | Wall Thickness | Inner Layer Thickness | Standard Length | Max OFC Diameter (Blowing) |
|---|---|---|---|---|---|
| 32/26 mm | +0.3/-0.0 mm | 3.0 ± 0.2 mm | 0.24–0.36 mm | 1000 ± 100 m | 12 mm |
| 40/33 mm | +0.4/-0.0 mm | 3.5 ± 0.2 mm | 0.28–0.42 mm | 1000 ± 100 m | 16 mm |
| 50/42 mm | +0.5/-0.0 mm | 4.0 ± 0.3 mm | 0.32–0.48 mm | 1000 ± 100 m | 21 mm |
| 63/50 mm | +0.6/-0.0 mm | 6.5 ± 0.40 mm | 0.36–0.54 mm | 500 ± 50 m | 25 mm (144 fibres) |
| 110/80 mm | +1.0/-0.0 mm | 15.0 ± 0.60 mm | 0.56–0.84 mm | 200 ± 20 m | 40 mm (576 fibres) |
Berlia Compliance: We manufacture all five standard sizes with precise dimensional control. Our inline ultrasonic thickness gauges and laser diameter measurement systems ensure every metre meets the tolerance requirements.
3.4 Pre-Installed Rope
When ordered, ducts are supplied with pre-installed polypropylene rope:
-
32/26, 40/33, 50/42 mm: 4 mm dia, min. 2% slackness
-
63/50, 110/80 mm: 6 mm dia
Berlia Compliance: We offer optional pre-installed ropes as per IS 5175, with the correct diameter and slackness for each duct size.
3.5 Tensile Strength & Elongation
-
Tensile strength at yield: ≥ 20 N/mm²
-
Elongation: ≥ 500%
-
Tested at 50 mm/min per ASTM F 2160 (Type IV specimens)
Berlia Compliance: Our ducts consistently exceed these values. We conduct tensile testing on every production batch.
3.6 Longitudinal Reversion
-
200 mm sample at 110 ± 2°C for 60 minutes
-
Dimensional change ≤ 3% in longitudinal direction
Berlia Compliance: Our optimized extrusion and cooling processes ensure minimal residual stress, resulting in reversion well below 3%.
3.7 Environmental Stress Crack Resistance
-
10% Igepal CO-630 at 50 ± 1°C for 96 hours
-
No failure/cracks
Berlia Compliance: Our HDPE compounds are selected for their superior ESCR performance. We routinely pass this test with zero failures.
3.8 Impact Strength
-
150 mm sample on 120° block
-
10 kg striker, 13 mm hemispherical nose, 1.5 m free fall
-
No crack or split
Berlia Compliance: Our ducts pass impact testing at 0°C as per IS: 12235 (Part-9) without cracking or splitting.
3.9 Crush Resistance
-
150 ± 2 mm sample, 50 kg dead load for 1 minute
-
Deflection with load: ≤ 10%
-
After 5 min recovery: ≤ 2%
Berlia Compliance: Our wall thickness and material formulation ensure excellent crush resistance, with deflection values well within limits.
3.10 Mandrel Test
-
150 mm mandrel, 3 mm less than ID
-
Must pass freely through 5 m duct bent to 5 m radius
Berlia Compliance: Our ducts are flexible yet strong, passing the mandrel test with ease.
3.11 Ovality Test
-
Difference between max and min OD at same cross-section
-
Measured 300 mm from end
Berlia Compliance: Our precision extrusion and cooling ensure ovality well within acceptable limits.
3.12 Coil Set
-
50 m length laid on ground must be straight
-
No bends, kinks, or deformation (except 5 m from each end)
Berlia Compliance: Our advanced winding and stress-relief processes produce zero coil set. The duct lays straight into the trench without snaking or waving.
3.13 Oxidation Induction Test
-
OIT ≥ 30 minutes as per Annexure-1
Berlia Compliance: Our compounds are stabilized with high-performance antioxidants, consistently achieving OIT values above 30 minutes.
3.14 Hydraulic Characteristics
| Test | Temp | Duration | Induced Stress |
|---|---|---|---|
| Type Test | 80°C | 165 hrs | 3.5 MPa |
| Acceptance Test | 80°C | 48 hrs | 3.8 MPa |
-
No localized swelling, leakage, or burst
Berlia Compliance: Our ducts pass internal pressure creep rupture testing as per IS: 4984.
3.15 Internal Coefficient of Friction
-
Nylon Jacketed unarmoured OFC: ICF ≤ 0.06
-
HDPE Jacketed unarmoured OFC: ICF ≤ 0.20
Berlia Compliance: Our permanently lubricated inner layer delivers ICF values that meet or exceed these requirements, ensuring smooth, long-distance cable blowing.
3.16 Identification Markings
-
Indelible ink markings every metre
-
Service Provider/Purchaser, Telephone Emblem, Manufacturer’s name, Duct name & size
-
Composite number: PXXSSSS DDMMYY
-
Sequential marking every metre
Berlia Compliance: Every Berlia duct is marked with all required information using high-durability ink that withstands storage and installation.
3.17 Optical Fibre Cable Blowing Test
-
1 km for 32/26, 40/33, 50/42 mm; 500 m for 63/50 mm
-
Bends in horizontal and vertical planes, raise in middle
-
Two couplings included
-
Blow in ≤ 35 minutes (for 1 km), no visible damage
-
Blow out, inspect, blow in again
Berlia Compliance: Our ducts are tested with actual OFC blowing to verify installation performance. The permanent lubricant layer ensures fast, damage-free cable installation.
3.18 Density
-
0.940–0.958 g/cc at 27°C
-
Difference from raw material ≤ 0.003 g/cc
Berlia Compliance: Our process control ensures density consistency between raw material and finished duct.
3.19 Melt Flow Rate
-
Change in MFR due to processing ≤ 30%
Berlia Compliance: Our extrusion parameters are optimized to minimize polymer degradation, keeping MFR change well below 30%.
3.20 Ash Content
-
≤ 0.3%
Berlia Compliance: Our formulations use high-purity additives, keeping ash content minimal.
3.21 Colour Fading Test
-
ASTM D 1712
-
No discolouration
Berlia Compliance: Our UV-stabilized colour master batches resist fading even after prolonged exposure.
3.22 UV Stabiliser Test
-
UV-B lamps, 0.63 W/m²/nm
-
Cycle: 4 hrs UV at 60°C + 4 hrs condensation at 50°C
-
Total: 720 hrs
-
Tensile strength variation ≤ 20%
Berlia Compliance: Our ducts are formulated with Hindered Amine Light Stabilisers (HALS) at ≥ 0.15% and pass the 720-hour UV aging test with minimal tensile loss.
4. PLB HDPE Duct Accessories
4.1 Plastic Couplers (Clause 5.1a)
-
Push-fit or Compression type
-
Air/water tight joint
-
Air pressure test: 15 kg/cm² for 2 hours, no leakage
-
Material: Injection moulding grade HDPE or Polypropylene
-
Smooth internal bore (no step formation)
-
Manufacturer’s name engraved, removable caps
Berlia Compliance: We supply precision-moulded couplers that provide airtight, watertight joints. Each coupler is tested to 15 kg/cm² for 2 hours.
4.2 End Plug
-
Seals empty duct ends
-
Prevents dirt, water, moisture, insects/rodents
-
Air tightness: 1 bar for 30 minutes
Berlia Compliance: Our end plugs are manufactured from high-grade rubber/plastic and pass the 1-bar, 30-minute airtightness test.
4.3 Cable Sealing Plug
-
Seals duct ends after cable installation
-
Accommodates standard OFC sizes with tolerance variations
-
Air tightness: 1 bar for 30 minutes
Berlia Compliance: Our cable sealing plugs are designed for a range of cable diameters and pass the required airtightness test.
4.4 End Cap
-
Hard rubber/suitable plastic
-
Fitted on both ends of duct coil
-
Prevents dust, mud, rainwater during transit/storage
Berlia Compliance: Every Berlia duct coil is fitted with durable end caps.
4.5 Pulling Force for Coupler Joints
| Duct Size | Minimum Pulling Force |
|---|---|
| 110/80 mm | 800 kgf |
| 63/50 mm | 550 kgf |
| 50/42 mm | 450 kgf |
| 40/33 mm | 320 kgf |
| 32/26 mm | 250 kgf |
-
Test: 15 minutes on Universal Tensile Testing Machine
Berlia Compliance: Our coupler joints exceed these pulling force requirements, ensuring joint integrity during installation.
4.6 Ageing Test for Accessories
-
Install accessory on duct
-
Test tightness (pass)
-
Age in air circulating oven at 70 ± 2°C for 168 hours
-
Cool to room temperature
-
Test tightness again (pass)
Berlia Compliance: Our accessories pass the 168-hour aging test and maintain airtightness.
4.7 Additional Tools
-
Rotary Duct Cutter
-
C-Spanner
-
Chamfering Tool
-
Blowing Equipment (Min 8 bar, Max 12 bar, 10 m³/min)
Berlia Compliance: We provide recommendations and specifications for all required installation tools.
5. Type Approval & Acceptance Testing
5.1 Type Approval Sampling
-
Single colour/size: 5 ducts offered
-
Multi colour/size: Min 2 ducts per colour per size, min 5 total
-
UV ageing: 1 duct per size per colour
-
Blowing test: 2 ducts per size
-
All other tests: All 5 ducts
Berlia Compliance: We provide all required samples for type approval and have successfully obtained type approval certificates for our PLB HDPE ducts.
5.2 Acceptance Tests
Visual & Dimensional :
-
Lot-based sampling with first and second sample sizes
-
Acceptance/rejection criteria as per table
Acceptance Tests:
-
Tensile Strength & Elongation
-
Longitudinal Reversion
-
Environmental Stress Crack Resistance
-
Impact Strength
-
Crush Resistance
-
Oxidation Induction Test
-
Hydraulic Characteristics
-
Internal Coefficient of Friction
Berlia Compliance: We have a fully equipped in-house testing laboratory and also utilize TEC-designated CAB/accredited laboratories for type testing. Every production lot is tested as per the sampling plan.
6. Storage, Packing & Delivery
-
Stored to prevent performance degradation
-
Coils of suitable size for safe delivery
-
Minimum inner bending diameter: 18 × outer diameter
Berlia Compliance: Our ducts are coiled on sturdy drums/spools with the correct minimum bending diameter and delivered in protective packaging.
7. Quality Requirements of Manufacturing System
-
ISO 9001:2015 (or latest) accreditation
-
Quality plan describing quality assurance system
Berlia Compliance: Berlia is an ISO 9001:2015 certified manufacturer. Our quality management system covers every stage from raw material sourcing to final dispatch. We maintain detailed quality plans and records for full traceability.
8. Test Methods
Oxidation Induction Test (OIT)
-
Sample conditioned at 68 ± 1°C for 8 hours
-
Cooled at room temperature for 16+ hours
-
DSC testing with nitrogen purge, then oxygen at 199 ± 1°C
-
Induction time ≥ 30 minutes
Berlia Compliance: We perform OIT testing using calibrated Differential Scanning Calorimeters as per the prescribed method.
Internal Coefficient of Friction (ICF)
-
450° wrap on 750 mm diameter fixture
-
25 kg tail weight
-
Extensometer at 500 mm/min
-
Formula: ICF = loge(T1/T2) / Q
Berlia Compliance: Our ICF testing confirms values ≤ 0.06 for nylon-jacketed OFC and ≤ 0.20 for HDPE-jacketed OFC.
9. Why Berlia?
| TEC Requirement | Berlia Compliance |
|---|---|
| Two-layer co-extruded construction | ✅ Advanced co-extrusion technology |
| 8 colour options with white stripes | ✅ All colours available |
| 5 standard sizes (32/26 to 110/80 mm) | ✅ Full range manufactured |
| 50-year service life | ✅ Engineered for 50+ years |
| Permanent lubricant layer | ✅ Integrally bonded, non-migrating |
| ICF ≤ 0.06 (nylon OFC) | ✅ Meets/exceeds |
| OIT ≥ 30 minutes | ✅ Consistently passes |
| UV stabilization ≥ 0.15% HALS | ✅ Compliant |
| ISO 9001:2015 | ✅ Certified |
| Type approval from TEC | ✅ Obtained |
10. Conclusion
The TEC/GR/FA/CDS-008/04/AUG-19 specification is not just a set of requirements — it’s a promise of quality, durability, and performance for India’s underground optical fibre infrastructure. At Berlia, we don’t just meet this standard; we exceed it at every clause.
From raw material selection to co-extrusion, from dimensional accuracy to friction performance, from UV stabilization to 50-year service life — every Berlia PLB HDPE duct is manufactured to comply with the highest technical standards.
When you choose Berlia, you choose:
-
Certified compliance with TEC/GR/FA/CDS-008/04/AUG-19
-
Proven performance in real-world optical fibre blowing installations
-
Peace of mind knowing your underground network is protected for decades
Contact Berlia today to discuss your PLB HDPE duct requirements and receive a detailed compliance certificate for your project.